H7 Hole Tolerance and Fits From ISO 286 to Final Inspection

Table of Contents

H7 hole tolerance tells you the size limits of the hole. The matching shaft tolerance determines how much room the parts have when they come together. A Ø25 H7 hole can have at least 0.007 mm of diametral clearance with a g6 shaft, while the same hole paired with h6 can reach line-to-line size at the tolerance limits. That difference matters if the shaft must slide into place without force.

Use this guide to read the ISO 286 hole tolerance table for Ø10 and Ø25 mm, calculate the clearance with two shaft tolerance bands, and specify how the bore will be accepted after the final surface treatment.

How to read H7 hole tolerance in ISO 286

In Ø25 H7, 25 mm is the nominal diameter. The capital H locates the hole tolerance band with its lower deviation at zero. The number 7 identifies the IT7 tolerance grade. The width of that band depends on the nominal diameter, so start with the size interval in the table. ISO 286-1 explains the system and ISO 286-2 provides the limit deviations for holes and shafts. ISO 286-1 and ISO 286-2.

Add the lower deviation to nominal to get the minimum permitted hole diameter. Add the upper deviation to get the maximum. The tables often express deviations in micrometers. Divide by 1,000 to convert them to millimeters before adding them to the nominal size. Pay attention to endpoints. A nominal diameter of exactly 10 mm belongs to the interval over 6 mm through 10 mm inclusive. The next interval starts above 10 mm.

H7 hole tolerance chart for two nominal diameters
Nominal diameter ISO 286 size interval Lower deviation Upper deviation Hole limits
Ø10 mm Over 6 through 10 mm 0 µm +15 µm 10.000–10.015 mm
Ø25 mm Over 18 through 30 mm 0 µm +21 µm 25.000–25.021 mm

For Ø10 H7, the calculation is 10.000 + 0.000 = 10.000 mm and 10.000 + 0.015 = 10.015 mm. For Ø25 H7, it is 25.000 + 0.000 = 25.000 mm and 25.000 + 0.021 = 25.021 mm. Read the shaft deviations from the shaft table for the same nominal diameter. The lowercase letter identifies a shaft tolerance band. Elesa+Ganter tolerance tables and MISUMI g6 shaft data.

Calculate the H7 hole fit with g6 and h6 shafts

Minimum diametral clearance equals the smallest permitted hole minus the largest permitted shaft. Maximum diametral clearance equals the largest permitted hole minus the smallest permitted shaft. Use the limits of each part, since any conforming hole may be paired with any conforming shaft when parts are interchangeable. A negative result indicates interference at that combination of limits.

Worst-case diametral clearance with g6 and h6 shafts
Fit Shaft limits (mm) Minimum clearance (mm) Maximum clearance (mm)
Ø10 H7/g6 9.986–9.995 10.000 − 9.995 = 0.005 10.015 − 9.986 = 0.029
Ø10 H7/h6 9.991–10.000 10.000 − 10.000 = 0.000 10.015 − 9.991 = 0.024
Ø25 H7/g6 24.980–24.993 25.000 − 24.993 = 0.007 25.021 − 24.980 = 0.041
Ø25 H7/h6 24.987–25.000 25.000 − 25.000 = 0.000 25.021 − 24.987 = 0.034
25 mm tolerance bands in micrometers. H7 hole 0 to +21, g6 shaft −20 to −7, and h6 shaft −13 to 0.
At 25 mm nominal, the g6 band ends 7 µm below the start of H7. The h6 band reaches the H7 lower limit at zero deviation.

In both sizes, g6 gives positive calculated clearance at the closest combination. It also increases the maximum clearance compared with h6. Use the two endpoints when selecting the fit. A locating feature may allow less play than a sliding feature, while a part that must assemble freely needs enough minimum clearance for its actual operating and assembly conditions. A zero minimum with H7/h6 leaves no size allowance at the closest limit. Misalignment, form error, burrs, and temperature differences can affect how the real parts go together.

Decide how much play the function can tolerate and whether you need clearance, transition, or interference. Then select and check the shaft band against that requirement. If the fit depends on roundness, cylindricity, or alignment to another feature, specify those requirements on the drawing and plan their inspection separately from diameter.

The clearance in the table is diametral. For concentric cylinders, the gap on each side is half that value. Use the same convention when comparing the fit with an assembly requirement, especially if the requirement came from a radial displacement or a side clearance in CAD. Review the intended assembly temperature and service range when the hole and shaft use different materials. The drawing limits establish the size stack at the stated reference condition. The assembled clearance can change as the two parts expand by different amounts.

Define the finished bore after plating or anodizing

State the condition that governs the fit on both component drawings. If the Ø25 H7 limit applies to the delivered plated bore, the acceptance range is 25.000–25.021 mm after plating. The pre-finish machining window is a process target developed with the finisher. Mark any masked regions and where the coating boundary may fall. If the shaft is also coated, calculate the fit using the finished limits of both parts.

For illustration, a bore measured at 25.018 mm before treatment would finish at approximately 25.006 mm if the effective inward change were 0.006 mm on each wall. That one example falls within Ø25 H7. The actual machining window must allow for variation in both cutting and finishing. Ask the finisher about coverage at the working depth of the bore. For anodizing, the net change can include both oxide growth and material removed by pretreatment. Confirm the change on trial parts and measure the actual finished bore. Machining tolerances after anodizing and Aluminum Anodizers Council dimensional guidance.

Choose a plain plug gauge or a bore measurement

GO and NO-GO plug gauges for pass or fail

Use a calibrated plain limit plug gauge designed for the bore tolerance and its required inspection depth. For a hole, the GO gauge checks the small-size limit and should pass through the specified gauging length under the agreed technique. The NO-GO gauge checks the large-size limit using the specified engagement rule. Clean the hole and gauge, check the entry for damage or burrs, and follow the inspection procedure without forcing either end. Confirm access and gauging length on blind or stepped bores before ordering the gauge.

Specify the gauge standard, gauge tolerance, wear allowance where applicable, and calibration requirements with the gauge maker. The workpiece limits are the starting point for gauge selection. The actual gauge dimensions follow the applicable design rules and gauge tolerances. Record the gauge ID and result for traceability. ISO 1938-1 plain limit gauges.

Variable measurement for actual diameters

Use a suitable bore measuring instrument when you need numerical readings for first article approval, coating trials, or process monitoring. Select the instrument and master for the diameter, depth, and tolerance. Define the measurement locations and orientations so repeated readings can reveal changes with depth or direction. Record the actual values, units, and finished condition. If roundness or cylindricity matters, choose a measurement strategy that can verify the specified form. A pass or fail entry from a plug gauge cannot supply actual bore diameter or a record of how much coating changed it.

For a bore with a lead-in chamfer and a shoulder, label the length of the cylindrical fit surface on the drawing or inspection plan. Position the measurement contacts on that surface. A reading on the chamfer tells you about the entry geometry and can make the bore appear oversized. Establish how parts and masters are conditioned before measurement, and agree on the decision rule for readings close to a limit. This is especially important when two shops will inspect the same feature.

Agree on what the sample represents

Specify the lot definition, inspection unit, bore locations, measurement condition, and lot acceptance rule. For a housing with two critical bores, decide whether both bores on every sampled housing must be checked and whether one failed bore makes that housing a nonconforming unit. Counting failed bores and counting failed housings give different results. Keep the unit consistent across the sample size, recorded findings, and acceptance rule.

When using a lot-by-lot attributes plan, agree on the applicable standard, inspection level, AQL, sample size, and acceptance and rejection numbers. For a feature that requires every part to be gauged, state the coverage separately. Identify the first article readings needed to qualify the process and the records needed for repeat lot release. If a finished bore fails, record the part, lot, gauge or instrument, and failure mode so disposition can follow the agreed plan. ISO 2859-1 attributes sampling and CNC machining inspection guide.

Use the lot definition to preserve traceability across operations. If one machining run is split across finishing batches, record those batches and agree how the sampling plan covers them. Select parts using the agreed sampling method. A first article measured before coating establishes an intermediate result. A final sample taken after coating establishes evidence for the delivered lot. An agreed lot decision rule determines whether to release or hold the lot when a sample fails.

Send the three fit inputs with your RFQ

Send the nominal bore diameter, mating shaft tolerance class or limits, and final surface treatment. Identify whether each size applies before or after finishing. Attach the drawing revision, usable bore depth, production quantity, and any form or position requirements. State whether you need a calibrated GO and NO-GO result, actual bore readings, or both, and specify the lot sampling or full inspection scope. Send your drawing to Easiahome for a fit and inspection review.